Qlogic光纤卡安装配置记录及参考

Last Updated: Saturday, 2004-11-06 19:59 Eygle
    

 

 

 

Qlogic光纤卡安装配置相对简单,但是同样的,为了是主机可以识别多个LUN信息,需要修改sd.conf配置文件。

 

以下是我的sd.conf的配置,供参考:

#
# Copyright (c) 1992, by Sun Microsystems, Inc.
#
#ident  "@(#)sd.conf    1.9     98/01/11 SMI"

name="sd" class="scsi" class_prop="atapi"
        target=0 lun=0;

name="sd" class="scsi" class_prop="atapi"
        target=1 lun=0;

name="sd" class="scsi" class_prop="atapi"
        target=2 lun=0;

name="sd" class="scsi" class_prop="atapi"
        target=3 lun=0;

name="sd" class="scsi"
        target=4 lun=0;

name="sd" class="scsi"
        target=5 lun=0;

name="sd" class="scsi"
        target=6 lun=0;

name="sd" class="scsi"
        target=8 lun=0;

name="sd" class="scsi"
        target=9 lun=0;

name="sd" class="scsi"
        target=10 lun=0;

name="sd" class="scsi"
        target=11 lun=0;

name="sd" class="scsi"
        target=12 lun=0;

name="sd" class="scsi"
        target=13 lun=0;

name="sd" class="scsi"
        target=14 lun=0;

name="sd" class="scsi"
        target=15 lun=0;
name="sd" parent="qla2300" target=0 lun=0;
name="sd" parent="qla2300" target=0 lun=1;
name="sd" parent="qla2300" target=0 lun=2;
name="sd" parent="qla2300" target=0 lun=3;
name="sd" parent="qla2300" target=0 lun=4;
name="sd" parent="qla2300" target=0 lun=5;
name="sd" parent="qla2300" target=0 lun=6;
name="sd" parent="qla2300" target=0 lun=7;
name="sd" parent="qla2300" target=1 lun=0;
name="sd" parent="qla2300" target=1 lun=1;
name="sd" parent="qla2300" target=1 lun=2;
name="sd" parent="qla2300" target=1 lun=3;
name="sd" parent="qla2300" target=1 lun=4;
name="sd" parent="qla2300" target=1 lun=5;
name="sd" parent="qla2300" target=1 lun=6;
name="sd" parent="qla2300" target=1 lun=7;
name="sd" parent="qla2300" target=2 lun=0;
name="sd" parent="qla2300" target=3 lun=0;
name="sd" parent="qla2300" target=4 lun=0;
name="sd" parent="qla2300" target=5 lun=0;
name="sd" parent="qla2300" target=6 lun=0;
name="sd" parent="qla2300" target=7 lun=0;
name="sd" parent="qla2300" target=8 lun=0;
name="sd" parent="qla2300" target=9 lun=0;
name="sd" parent="qla2300" target=10 lun=0;
name="sd" parent="qla2300" target=11 lun=0;
name="sd" parent="qla2300" target=12 lun=0;
name="sd" parent="qla2300" target=13 lun=0;
name="sd" parent="qla2300" target=14 lun=0;
name="sd" parent="qla2300" target=15 lun=0;
name="sd" parent="qla2300" target=16 lun=0;
name="sd" parent="qla2300" target=17 lun=0;
name="sd" parent="qla2300" target=17 lun=1;
name="sd" parent="qla2300" target=17 lun=2;
name="sd" parent="qla2300" target=17 lun=3;		
			  

 

配置完成以后,使用reboot -- -r选项重新启动主机系统,之后可以正常发现分配给主机系统的多个LUN。

 

# format
Searching for disks...done

c2t2d0: configured with capacity of 133.21GB
c2t2d1: configured with capacity of 266.41GB
c2t2d2: configured with capacity of 199.81GB
c2t2d3: configured with capacity of 60.00GB
c2t2d4: configured with capacity of 1023.94MB
c2t2d5: configured with capacity of 133.21GB
c2t2d6: configured with capacity of 60.00GB
c2t2d7: configured with capacity of 1023.94MB
c2t3d0: configured with capacity of 133.21GB
c2t3d1: configured with capacity of 266.41GB
c2t3d2: configured with capacity of 199.81GB
c2t3d3: configured with capacity of 60.00GB
c2t3d4: configured with capacity of 1023.94MB
c2t3d5: configured with capacity of 133.21GB
c2t3d6: configured with capacity of 60.00GB
c2t3d7: configured with capacity of 1023.94MB
c3t2d0: configured with capacity of 133.21GB
c3t2d1: configured with capacity of 266.41GB
c3t2d2: configured with capacity of 199.81GB
c3t2d3: configured with capacity of 60.00GB
c3t2d4: configured with capacity of 1023.94MB
c3t2d5: configured with capacity of 133.21GB
c3t2d6: configured with capacity of 60.00GB
c3t2d7: configured with capacity of 1023.94MB
c3t3d0: configured with capacity of 133.21GB
c3t3d1: configured with capacity of 266.41GB
c3t3d2: configured with capacity of 199.81GB
c3t3d3: configured with capacity of 60.00GB
c3t3d4: configured with capacity of 1023.94MB
c3t3d5: configured with capacity of 133.21GB
c3t3d6: configured with capacity of 60.00GB
c3t3d7: configured with capacity of 1023.94MB
emcpower0a: configured with capacity of 133.21GB
emcpower1a: configured with capacity of 1023.94MB
emcpower2a: configured with capacity of 60.00GB
emcpower3a: configured with capacity of 133.21GB
emcpower4a: configured with capacity of 1023.94MB
emcpower5a: configured with capacity of 60.00GB
emcpower6a: configured with capacity of 199.81GB
emcpower7a: configured with capacity of 266.41GB


AVAILABLE DISK SELECTIONS:
       0. c1t0d0 
          /pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e01077a8d1,0
       1. c1t1d0 
          /pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e01077cb01,0
       2. c1t2d0 
          /pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e0107823d1,0
       3. c1t3d0 
          /pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e010782471,0
       4. c1t4d0 
          /pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e0107a6b21,0
       5. c1t5d0 
          /pci@8,600000/SUNW,qlc@2/fp@0,0/ssd@w500000e0107aacc1,0
       6. c2t2d0 
          /pci@9,700000/fibre-channel@4/sd@2,0
       7. c2t2d1 
          /pci@9,700000/fibre-channel@4/sd@2,1
       8. c2t2d2 
          /pci@9,700000/fibre-channel@4/sd@2,2
       9. c2t2d3 
          /pci@9,700000/fibre-channel@4/sd@2,3
      10. c2t2d4 
          /pci@9,700000/fibre-channel@4/sd@2,4
      11. c2t2d5 
          /pci@9,700000/fibre-channel@4/sd@2,5
      12. c2t2d6 
          /pci@9,700000/fibre-channel@4/sd@2,6
      13. c2t2d7 
          /pci@9,700000/fibre-channel@4/sd@2,7
      14. c2t3d0 
          /pci@9,700000/fibre-channel@4/sd@3,0
      15. c2t3d1 
          /pci@9,700000/fibre-channel@4/sd@3,1
      16. c2t3d2 
          /pci@9,700000/fibre-channel@4/sd@3,2
      17. c2t3d3 
          /pci@9,700000/fibre-channel@4/sd@3,3
      18. c2t3d4 
          /pci@9,700000/fibre-channel@4/sd@3,4
      19. c2t3d5 
          /pci@9,700000/fibre-channel@4/sd@3,5
      20. c2t3d6 
          /pci@9,700000/fibre-channel@4/sd@3,6
      21. c2t3d7 
          /pci@9,700000/fibre-channel@4/sd@3,7
      22. c3t2d0 
          /pci@8,700000/fibre-channel@4/sd@2,0
      23. c3t2d1 
          /pci@8,700000/fibre-channel@4/sd@2,1
      24. c3t2d2 
          /pci@8,700000/fibre-channel@4/sd@2,2
      25. c3t2d3 
          /pci@8,700000/fibre-channel@4/sd@2,3
      26. c3t2d4 
          /pci@8,700000/fibre-channel@4/sd@2,4
      27. c3t2d5 
          /pci@8,700000/fibre-channel@4/sd@2,5
      28. c3t2d6 
          /pci@8,700000/fibre-channel@4/sd@2,6
      29. c3t2d7 
          /pci@8,700000/fibre-channel@4/sd@2,7
      30. c3t3d0 
          /pci@8,700000/fibre-channel@4/sd@3,0
      31. c3t3d1 
          /pci@8,700000/fibre-channel@4/sd@3,1
      32. c3t3d2 
          /pci@8,700000/fibre-channel@4/sd@3,2
      33. c3t3d3 
          /pci@8,700000/fibre-channel@4/sd@3,3
      34. c3t3d4 
          /pci@8,700000/fibre-channel@4/sd@3,4
      35. c3t3d5 
          /pci@8,700000/fibre-channel@4/sd@3,5
      36. c3t3d6 
          /pci@8,700000/fibre-channel@4/sd@3,6
      37. c3t3d7 
          /pci@8,700000/fibre-channel@4/sd@3,7
      38. emcpower0a 
          /pseudo/emcp@0
      39. emcpower1a 
          /pseudo/emcp@1
      40. emcpower2a 
          /pseudo/emcp@2
      41. emcpower3a 
          /pseudo/emcp@3
      42. emcpower4a 
          /pseudo/emcp@4
      43. emcpower5a 
          /pseudo/emcp@5
      44. emcpower6a 
          /pseudo/emcp@6
      45. emcpower7a 
          /pseudo/emcp@7
Specify disk (enter its number): 1
selecting c1t1d0
[disk formatted]


FORMAT MENU:
        disk       - select a disk
        type       - select (define) a disk type
        partition  - select (define) a partition table
        current    - describe the current disk
        format     - format and analyze the disk
        repair     - repair a defective sector
        label      - write label to the disk
        analyze    - surface analysis
        defect     - defect list management
        backup     - search for backup labels
        verify     - read and display labels
        save       - save new disk/partition definitions
        inquiry    - show vendor, product and revision
        volname    - set 8-character volume name
        !     - execute , then return
        quit
format> q
# 					  

 

使用powerpath查看通路状态:

 

# powermt display dev=all
Pseudo name=emcpower6a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A91000004B1E21C02FD911 [LUN 5]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
### HW Path                 I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4     c2t2d2s0   SP A1     active  alive      0      0
1281 pci@9/fibre-channel@4     c2t3d2s0   SP B1     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t2d2s0   SP A0     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t3d2s0   SP B0     active  alive      0      0

Pseudo name=emcpower3a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A910002070EBBEBF2FD911 [LUN 2]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP B, current=SP B
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
### HW Path                 I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4     c2t2d5s0   SP A1     active  alive      0      0
1281 pci@9/fibre-channel@4     c2t3d5s0   SP B1     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t2d5s0   SP A0     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t3d5s0   SP B0     active  alive      0      0

Pseudo name=emcpower1a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A9100030349D70BF2FD911 [LUN 0]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP B, current=SP B
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
### HW Path                 I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4     c2t2d7s0   SP A1     active  alive      0      0
1281 pci@9/fibre-channel@4     c2t3d7s0   SP B1     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t2d7s0   SP A0     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t3d7s0   SP B0     active  alive      0      0

Pseudo name=emcpower5a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A9100034F5B208C02FD911 [LUN 4]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
### HW Path                 I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4     c2t2d3s0   SP A1     active  alive      0      0
1281 pci@9/fibre-channel@4     c2t3d3s0   SP B1     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t2d3s0   SP A0     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t3d3s0   SP B0     active  alive      0      0

Pseudo name=emcpower2a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A9100050F80AA1BF2FD911 [LUN 1]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP B, current=SP B
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
### HW Path                 I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4     c2t2d6s0   SP A1     active  alive      0      0
1281 pci@9/fibre-channel@4     c2t3d6s0   SP B1     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t2d6s0   SP A0     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t3d6s0   SP B0     active  alive      0      0

Pseudo name=emcpower7a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A910005CD3952EC02FD911 [LUN 6]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
### HW Path                 I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4     c2t2d1s0   SP A1     active  alive      0      0
1281 pci@9/fibre-channel@4     c2t3d1s0   SP B1     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t2d1s0   SP A0     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t3d1s0   SP B0     active  alive      0      0

Pseudo name=emcpower4a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A910007EFC11F4BF2FD911 [LUN 3]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP A
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
### HW Path                 I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4     c2t2d4s0   SP A1     active  alive      0      0
1281 pci@9/fibre-channel@4     c2t3d4s0   SP B1     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t2d4s0   SP A0     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t3d4s0   SP B0     active  alive      0      0

Pseudo name=emcpower0a
CLARiiON ID=CK200041200044 [db880-1]
Logical device ID=60060160D2A9100096E1432DC62FD911 [LUN 7]
state=alive; policy=CLAROpt; priority=0; queued-IOs=0
Owner: default=SP A, current=SP B
==============================================================================
---------------- Host ---------------   - Stor -   -- I/O Path -  -- Stats ---
### HW Path                 I/O Paths    Interf.   Mode    State  Q-IOs Errors
==============================================================================
1281 pci@9/fibre-channel@4     c2t2d0s0   SP A1     active  alive      0      0
1281 pci@9/fibre-channel@4     c2t3d0s0   SP B1     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t2d0s0   SP A0     active  alive      0      0
1280 pci@8/fibre-channel@4     c3t3d0s0   SP B0     active  alive      0      0
						

 

作为对比,你可以参考一下Emulex光纤卡的配置方法:

http://www.eygle.com/unix/Emulex_LightPulse_FC9002L_Solaris9_Install.htm

 

 

本文作者:
eygle,Oracle技术关注者,来自中国最大的Oracle技术论坛itpub.
www.eygle.com是作者的个人站点.你可通过Guoqiang.Gai@gmail.com来联系作者.欢迎技术探讨交流以及链接交换.


原文出处:

http://www.eygle.com/unix/Qlogic.HBA.Config.log.htm

 


如欲转载,请注明作者与出处.并请保留本文的连接.

回首页