EMC损坏硬盘更换及恢复过程
modb.pro

更换EMC损坏的磁盘以后,盘阵会自动开始把hot spare备份的数据恢复过来。
然后把启用的hot spare盘恢复到初始备用状态。

我们可以通过命令来观察这一过程,首先看新换上来的硬盘,注意此时的状态为Equalizing,也就是正在进行平衡的过程:
# navicli -h 172.16.9.5 getdisk 1_0_1
Bus 1 Enclosure 0  Disk 1
Vendor Id:               SEAGATE 
Product Id:              ST373307 CLAR72 
Product Revision:        7A0A
Lun:                     6 
Type:                    6: RAID5 
State:                   Equalizing
Hot Spare:               6: NO 
Prct Rebuilt:            6: 100 
Prct Bound:              6: 100 
Serial Number:           3HZ6TL7F
Sectors:                 139681792 (68204)
Capacity:                68238
Private:                 6: 69704 
Bind Signature:          0x5cf2, 0, 1
Hard Read Errors:        0
Hard Write Errors:       0
Soft Read Errors:        0
Soft Write Errors:       0
Read Retries:     N/A
Write Retries:    N/A
Remapped Sectors:        N/A
Number of Reads:         980562
Number of Writes:        1107168
Number of Luns:          1
Raid Group ID:           3
Clariion Part Number:    DG118032459  
Request Service Time:    N/A
Read Requests:           980562
Write Requests:          1107168
Kbytes Read:             99788880
Kbytes Written:          70098518
Stripe Boundary Crossing: 2704586

此时hot spare盘的状态为Enabled,其替代的硬盘为:1_0_1
# navicli -h 172.16.9.5 getdisk 1_0_14
Bus 1 Enclosure 0  Disk 14
Vendor Id:               SEAGATE 
Product Id:              ST314680 CLAR72 
Product Revision:        7A0A
Lun:                     102 
Type:                    102: Hot Spare 
State:                   Enabled
Hot Spare:               102: YES 
Hot Spare Replacing:     1_0_1
....

当重算完成以后,1_0_1的状态变为Enabled
# navicli -h 172.16.9.5 getdisk 1_0_1
Bus 1 Enclosure 0  Disk 1
Vendor Id:               SEAGATE 
Product Id:              ST373307 CLAR72 
Product Revision:        7A0A
Lun:                     6 
Type:                    6: RAID5 
State:                   Enabled
Hot Spare:               6: NO 
......

而此时的hot spare盘状态重新变为:Hot Spare Ready,至此恢复过程彻底完成。
# navicli -h 172.16.9.5 getdisk 1_0_14
Bus 1 Enclosure 0  Disk 14
Vendor Id:               SEAGATE 
Product Id:              ST314680 CLAR72 
Product Revision:        7A0A
Lun:                     102 
Type:                    102: Hot Spare 
State:                   Hot Spare Ready
Hot Spare:               102: YES 
Hot Spare Replacing:     Inactive
....


历史上的今天...
    >> 2015-09-14文章:
    >> 2011-09-14文章:
    >> 2009-09-14文章:
    >> 2008-09-14文章:
    >> 2006-09-14文章:
           高级复制ORA-25207错误解决
    >> 2004-09-14文章:

By eygle on 2005-09-14 22:14 | Comments (7) | System | 433 |

7 Comments

没有使用过EMC的阵列,
不过还是开了眼界

我这的CX400现在坏了第一块盘,但是上面说0-3块盘上装了阵列软件,如果拔掉或移动这几块盘的话阵列会用不了,该怎么办呢?

那三块盘做的是Raid5啊,当然可以换了,你怕什么。

study

无意发现,不错!

我公司专注在EMC方面.

无意发现,不错!

我公司专注在EMC方面,如需帮助,可与我联系!
Email:sam.lai@tom.com
MOBILE:13710727245 Sam

专注EMC、HDS存储整机、备件、服务!