August 26, 2005
EMC的FC Disk坏了一块
作者:eygle
出处:http://blog.eygle.com
此前这块磁盘已经报警,现在终于是坏了。这次的教训是,一旦磁盘报警就应该立即更换。服务商那边曾提出先清除警报状态,再作观察,结果没等到动作Bus 0 Enclosure 0 Disk 10就彻底损坏了。
Hot Spare盘顶上,没有影响系统正常运行。
从navicli我们可以看到故障磁盘已经被removed,Hotspare盘已经启用。
故障盘:
# navicli -h 172.16.9.5 getdisk 0_0_10 Bus 0 Enclosure 0 Disk 10 State: Removed |
热备盘:
# navicli -h 172.16.9.5 getdisk 0_0_14 Bus 0 Enclosure 0 Disk 14 Vendor Id: SEAGATE Product Id: ST314680 CLAR72 Product Revision: 7A0A Lun: 101 Type: 101: Hot Spare State: Enabled Hot Spare: 101: YES Hot Spare Replacing: 0_0_10 Prct Rebuilt: 101: 100 Prct Bound: 101: 100 Serial Number: 3HY6TMN6 Sectors: 139681792 (68204) Capacity: 68238 Private: 101: 69704 Bind Signature: 0x80bd, 0, 14 Hard Read Errors: 0 Hard Write Errors: 0 Soft Read Errors: 0 Soft Write Errors: 0 Read Retries: N/A Write Retries: N/A Remapped Sectors: N/A Number of Reads: 303280 Number of Writes: 104340 Number of Luns: 1 Raid Group ID: 101 Clariion Part Number: DG118032458 Request Service Time: N/A Read Requests: 303280 Write Requests: 104340 Kbytes Read: 9240617 Kbytes Written: 1250471 Stripe Boundary Crossing: 0 |
.
Posted by eygle at 9:24 AM | Comments (3)